Hi Peter, I think you might be jumping the wrong terminals? It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. The filter is clean. Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Now it wont flip back on but it is still raining hard. Most heaters can operate on 120V/240V, either one. Ive tried everything. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. Intermittently meaning it could run for days then trip, I could reset the breaker and have it trip again within a few hours, or it could run for days. Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Does it turn on again by itself, about 20 minutes later (after cooling down)? If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. Products, learn Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Do you have any ideas?? Filter. To rule out the filter, if you have a multiport valve, run the pump on the Waste or Recirculate position. },
2 year warranty. I went out Toto shut it off so I could backwash and add chlorine. Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. Click OK to extend your time for an additional 0 minutes. Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. Any ideas as to what could be the problem? The problem lies, where the power dies as they say. After reinstalling, give it the full charge of DE powder, plus a little extra. Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. Please help! The breaker on the panel tripped. Theres no sound, when we hit the power switch no power. Monday Friday, 8 AM 5 PM. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. 2. loose pipe coming into pump, drawing air around fitting threads Sun was beating on it. I tried starting again one morning but the pump wont start. Please help! For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. Can I replace this pump housing or do I need a new pump? I have no display showing. That is usually what causes the rattle. {
Cavitation refers to a pump being starved for water, and as you describe the water level in the pump basket is low, but also the pump makes a grinding noise, like its gargling rocks. Cleaners will remove the grease/oils, and acid will remove scale deposits. Check the impeller and seal alignment. Wait for the number to. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. To view these documents, you will need to download the free Acrobat Reader, which My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. Well the electrician said it was a bad motor and to contact hayward to replace. I am getting air bubbles coming from my return jets in my pool. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? It trips 20amp breaker after running 5 or 10 second. Thanks! Please advise. Hi Jason, I would wait to spend the money, until certain that would be the fix. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. If there isnt any apparent damage, keep reading. We just opened our pool up cleaned everything out put new D.E. The third thing to check would be an obstruction on the pressure side of the pump, clogged impeller, clogged filter, closed return side valves or plugs in the wall. Air leaks are another source of priming issues. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. Never had an issue with the other motors we have had. Since that time the mechanical seal has failed four times each time within 2 months of operation. How Much Salt Belongs In Your Pool It has been in operation since mid May without and incident before yesterday. Hopefully it has a switch inside the pump so I can change it for 115. It shouldnt be overheating, not in twenty seconds, but I suppose it could. Hi Davy, I have a Hayward Super II which has been running well for years. Hi Don, we call that surging and it is usually caused by an air leak on the suction side, which is usually on the pump lid o-ring, or a loose threaded fitting, coming into the pump, or sometimes a leaky skimmer or main drain valve but the problem is always before the impeller You can use shaving cream around the pump lid, pipe and valves, turn on the pump, and see where it gets sucked in, or sometimes the problem is evident without such a messy test. If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. I replaced the entire pump motor and the same thing happened. Has worked fine until today. If all is good, there is a possibility that the breaker or GFCI outlet is bad. Also look for loose wires or corrosion (stored next to chlorine tabs during winter?) Not sure whats wrong. I have chalked all the connections and lubricated the basket seal. Is it plug and play? If flame is sensed with the gas valve off the control will go into lockout. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. This is our second season for this pump. Davy: Is my pool pump dead? I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Hi Andy, breakers are not usually screwed down, they snap in place, you can try pushing firmly on the front of the breaker with fingers, to be sure it is seated properly. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). Yes, if not grounded correctly, the GFCI will trip. Motor is connected to 220 volts and each phase consume 3.8 amps. They dont usually begin to flow like a gusher, but a steady trickle. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Im assuming that the motor makes no noise at all? It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. I just dont know when it was purchased or how to even find out from the previous owners. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. ), to see if air is drawing in around the fitting. When I try to turn on high speed it sounds like its jamming and then the breaker trips. 3200 ppm is the ideal level. I also noticed that the repaired motor },
Hi probably not related to the vacuuming, but sounds like a motor problem. If it is not, re-align your flow switch. The problem lies where the power dies! If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. But dont bypass GFCI protection, thats just to determine if its a motor problem or outlet problem. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. please update your current version of Internet Explorer or try using a different browser. I have a hayward pump installed as a new this March, 1.5 hp motor with a 23 inch filter to support a 12,000 gallons pool, it was working properly the first 3 months occasionally motor shut off and it wasnt by the breaker, since a week motor keep running only by 20 ,ins and suit off, touching the motor it is hot, I review filter pressure it is 15 psi, it is the same since installation. Bob. So you could cut off the pipe and cap it yes, although it might be worth investigating the repair cost the crack could be just 2 foot below the ground, near the pump/filter. Hi there, 30 psi is pretty high pressure, sounds like the pump is having trouble pushing thru are you using enough DE powder? Hi COnnie, great question! Now, if your motor has cooled off, but wont start again, or make any noise at all, as you say i would check the power (volts) going into the motor, put the multimeter probes (set on 240V+) onto the two brass terminals of the motor terminal board, where the two incoming wires connect. Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. Hi John hot plug? Can you manually get it to rev-up on a higher speed? pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; Whats that part called in case I do break it? With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. If regular loudness, its likely an air leak. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. The arrow at the top of the hex nut points in the direction of the water flow. Automatic restart 2 min after error is corrected. Third guess would be that the connections were not tight on the new motor. We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. They are easily replaceable. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. Inspect wiring for any loose or corroded connections. If there is input power, the fuse may have blown. If free, remove the Blue, Black and Red wires (page 4) from the drive Shut off power at the breaker to all pool equipment If flushing and draining does not help, it is time to open up the filter tank, remove the grid assy (or flex tube nest), and after cleaning very well with a hose, soak it in a DE filter cleaner solution (5-gal bucket works well for Perflex). I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. Fault with the pump wiring. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? If the pond is located below the pool equipment, then the pump and filter and pipes will drain down to that level, once the drain plugs are removed. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. Its that time of season to close the pool, I am probably going to close the pool and worry about the tripping breaker next year. Check it out, it could start a fire! Hi Chad, when a motor makes no noise at all, I suspect power issues. At the end of last season we noticed a leak. Pull the motor out of the pump and turn it on briefly, to see if the noise remains. "@type": "ImageObject",
Gas pressure is ok. Any ideas? Also, make sure you plug in the cell all the way. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. the 4th wire, the high speed wire. Like it is locked up. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
If you see no gears moving, the timer motor may be dead. We have parts for the Super pump. Vacuum hose air leaks from splits in an old hose. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. Learn more about pool care and repair. The water level in the pool is high enough, but Im getting a whirlpool in the skimmer basket, and the water returning back into the pool is so powerful, its creating a whirlpool and air bubbles I dont know what else to do? I removed the back of the pump and the yellow wire has a small black burn hole in it. This time around I purchased the t-3 cell model since my pool is below 15k gallons. Hi Shannon, assuming that your pump is single speed (not dual speed or variable speed), it runs at a constant 3450 RPM, and is not possible to run at a lower speed. it will not pull up off the pump basket. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. The pump is working fine, however only the low speed is working. Bobby, yes that would rule out the power source, or the outlet as being the problem. FYI I moved the voltage selector to 115. When, Swimming pool pumps that are noisy can keep you from enjoying peaceful naps by the pool, or can keep your neighbors up, In-Floor pool cleaners have been around since the 70's when they became the answer to the complaints about traditional pool cleaners. If your cell looks like 4B, follow the instructions below for cleaning your cell. The electrician also installed w new capacitors on the pump and still same problem. Just bought a hayward super II pump. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. I have a Hayward H250, when I turn it on the green heat light is lit and the heater seems to make a howling sound. If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. Water Features, View All Select Product to Register: Step 4: Enter the registration information for your product . Nothing seems to give it juice. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. "caption": "In The Swim Blog"
I have back washed the filter about 6 times in 1 month, and even soaked the filter (the DE fingers) in a cleaning solution and also soaked it in Muriatic Acid for about 30 minutes. The Pool is a Roman 23 in ground. goes on first, then the spring, then the slightly larger hole washer. Hi my spa empties into the pool when the spa is turned on. Hi Tommy, very loud pump could be that the pump overheated, because it lost prime, and this either damaged the shaft bearings or melted/warped the impeller and diffuser. Have a Hayward pump. Also make sure that the impeller wear ring is correctly facing, and that the seal plate and mounting screw are aligned properly, and that the diffuser and diffuser o-ring are seating properly. Could that be the voltage then or is there another possibility? {
Check the capacitor, for bulging, cracking, or melting. After resetting the switch 3 times yesterday,the pump is finally staying on. What would have caused this? A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. If none found, inspect your valve settings, on the equipment pad, and make sure everything is normal, and the cleaner water flow is not being throttled or bypassed. I have my pump to run each evening from 10:30pm to 9:30am. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. Reattach capacitor, replace rear cover and test motor again. Copyright 2022 In The Swim. Sean, Hi Sean, no worries. There are no leaks and the basket remains full with water. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. 4 New pump 2 years old. My heater is not turning on, I dont see an error message but the light next to the fire icon is not on but the light in the yellow triangle is on, any idea on what that means? Thanks for the reply! Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. I opened the back and was spinning the rod and it eventually started. Hi, like some of the other comments, when a pump basket doesnt fully fill with water, doesnt fully catch prime the first thing is to rule out an Air Leak, on the suction side. I just got my home back, I walked outside and pool level was well below jets. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. For multiport valves, the Spider Gasket inside can become worn, torn or twisted. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. Also, if there is a GFCI outlet connected, perhaps it is tripped? News Reporter Reveals On Live TV That Shes Been Secretly Recording . If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). Power is always present at supply input. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? Some very old pumps have impellers that need shimming from time to time, or resetting the distance from the volute, but thats with keyed shaft motors, on older bronze pumps (not plastic). Still nothing. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. Flipped the breakers back on this morning after problem fixed. Its likely good advice you are getting. The usual spot is the pipe that threads into the pump did you use Teflon tape and/or silicone sealant on the threads? If not, but the shaft and impeller spin freely remove the start capacitor, normally located in the motor rear, at 9 oclock, and write down the MFD number, and then order one online, or at a local electric motor repair shop. I just bought this pump 3-4 yrs ago? Hi, Is this a pump problem, priming problem (filter, pipes losing water somewhere)? I backwash and rinse and start again but it does the same thing. One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. It wont stop leaking. Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. If it clogs up again, you will need to break it down and manual clean, then soak in DE Filter Cleaner not so hard and the best cleaning, just a lot of little nuts and washers to remove and replace. I checked the breaker and plug connection and they were fine. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. I took the lid of the pump basket and cleaned the seal and placed it back on tightly, but there are small bubbles still coming out of the pool jets. This he says is because the drive is intermittently failing and the pump will need to be replaced. I had my Hayward pool/spa installed about 4 years ago. While the filter pump runs, you can here a drop for a millisecond every roughly 5 mins. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Hi and thanks for all this knowledge! Motor was only humming. I do not think its the breakerits relatively new. look for a hi-voltage/low-voltage diagram on the motor label. Round about 1990 the original AG pump and filter were replaced with used Hayward IG equipment. I have a Hayward Power-Flo Matrix and seems to be working fine when it is running the pool. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Check the shaft, to see that it is spinning freely, then check the wiring to be sure no bare wires are touching bare metal, or each other, or is corroded, and that all wiring is tight and clean. (PUMP and RETURN pipes). Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE then back to AUTO. An excessive temperature difference between the two thermistors (5 F or more) or an out of bounds condition on both sensors (less than 10F or greater than 180F) will result in the error code. This is actually the second motor in 6 months. I never had this problem before. We dont have mechanical time clocksit is all digital. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. the pump is working but not priming. Check the incoming voltage to be sure that you are within the range of 110V-125V. Yesterday we attempted to open our pool and the pump is acting really weird. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). Whats the problem. Backwashing or cleaning the pump basket is the usual fix. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. Also, because of this leak, would It cause my pressure to decrease? No matter what setting I put it in its backwashing the sand into the skimmer. 3. Is this normal? If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. With the pump off, remove the basket and reach your hand back into the eye of the impeller. If thats not it, check the valves on the suction side (skimmer/main drain) to be sure they are not leaking air. Im having an air leak problem with my pool. Salt chlorine generators are great products. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement.